Shimadzu Corporation

AA-7000 Atomic Absorption Spectrophotometer

  • The AA-7000 series of Atomic Absorption Spectrophotometers features high-sensitivity analysis, flexible system configuration, and a compact footprint for user-friendly operation.
  • The AA-7000 systems are the first AAs to employ a vibration sensor as standard. The AA-7000 series ensures efficient and comfortable operation in your laboratory.
  • The AA-7000 Series incorporates newly developed 3D double-beam optics. The optical system has been designed to produce its maximum performance for each measurement method through optimal adjustment of the light beam and light beam digital filter, and by using optical components that restrict light losses.
  • Advances in optics and a new graphite furnace design achieve improved lower limits of detection for furnace analysis. This superb analysis performance is possible in all fields.
  • Advanced safety technology
  • Trace Element Analysis by using Micro Sampling Technology.
  • Space-saving and energy-saving design

  • The AA-7000 series of Atomic Absorption Spectrophotometers features high-sensitivity analysis, flexible system configuration, and a compact footprint for user-friendly operation.
  • The AA-7000 systems are the first AAs to employ a vibration sensor as standard. The AA-7000 series ensures efficient and comfortable operation in your laboratory.
  • The AA-7000 Series incorporates newly developed 3D double-beam optics. The optical system has been designed to produce its maximum performance for each measurement method through optimal adjustment of the light beam and light beam digital filter, and by using optical components that restrict light losses.
  • Advances in optics and a new graphite furnace design achieve improved lower limits of detection for furnace analysis. This superb analysis performance is possible in all fields.
  • Advanced safety technology
  • Trace Element Analysis by using Micro Sampling Technology.
  • Space-saving and energy-saving design

  • Mercury Determination in Whole Blood Samples by Human Atomic Absorption (AA)

    This procedure describes the method of atomization with hydride (cold steam) to be used to determine the amount of mercury in Atomic Absorption (AA) in whole blood samples.

    Instrument: Shimadzu AA-7000 Atomik Absorpsiyon Spektrofotometre

  • Determination of Chromium in Whole Blood and Urine Samples in Human with Atomic Absorption (AA) (GFA)

    This procedure describes the electrothermal atomic absorption method (GFA) to be used to determine the amount of chromium in Atomic Absorption AA in whole blood and urine samples.

    Instrument: Shimadzu AA-7000 Atomik Absorpsiyon Spektrofotometre

  • Analysis of Selenium in Human Serum Samples with AA by Electrothermal AA Method

    This procedure describes the electrothermal atomic absorption method to be used to determine the amount of selenium in AA in complete serum samples.

    Instrument: Shimadzu AA-7000

  • Nickel Analysis by Electrothermal AA Method in Human Whole Blood and Urine Samples with AA

    This procedure describes the method of electrothermal atomic absorption to be used to determine the amount of nickel in AA in whole blood and urine samples.

    Instrument: Shimadzu AA-7000