Shimadzu Corporation

Thermal Desorption System | TD-30

The TD-30 Thermal Desorpiton System was developed as the optimal solution for gas and materials analysis. Its outstanding processing ability and excellent expandability provide strong support for all types of analysis, from work in research departments to quality control.

Outstanding Processing Ability and Basic Functionality

Extensive Sample Capacity Capable of Accommodating 120 Samples

The TD-30R Thermal Desorber has a maximum capacity of 120 samples, which allows processing a large number of samples via consecutive analyses overnight and on weekends. In addition, the sample tray is positioned lower down on the front of the instrument. This makes it easy to access even during analysis, and prevents tube positioning errors.


 

Efficient Analysis with the Overlap Function and Interrupt Function

With the TD-30 series Thermal Desorber, the overlap function enables the next sample to be pretreated during GC analysis, which shortens the analysis cycle time. In addition, the interrupt function enables unscheduled samples to be inserted even during consecutive analysis. As a result, a sample can be added after checking the results for a different sample, and an urgent sample analysis request can be accommodated.



















 

High-Sensitivity Analysis of High Boiling Point Components
Using a Sample Line with No Cold Points

With the TD-30 series, the entire sample line can be heated, so there are no cold points.
In addition, the sample line, including the transfer line, is designed to be short, which minimizes dead volume, and even highly adsorbent components and high boiling point components can be analyzed with high sensitivity.












 

 

Excellent Expandability Enables a Variety of Analyses

Hedging Risks with the Retrapping (Restore) Function

With the retrapping (restore) function, split samples desorbed from the tube and loaded into the GC-MS are once again trapped by the tube. Even if a problem occurs, the sample can be measured again, so that even precious trace samples can be analyzed with a sense of ease. In addition, with the TD-30R, the tube is cooled rapidly after desorption, so even low boiling point components can be restored.













 

Highly Accurate Quantitative Analysis
Using a Function That Automatically Adds an Internal Standard Substance

The TD-30R can automatically add a gaseous internal standard substance to the sample tube. Highly reliable quantitative results can be obtained, even for the analysis of trace components.












 

Highly Reliable Sample Management Using a Barcode Reader Function

The TD-30R can be optionally equipped with a barcode reader function. The barcode printed on the tube can be automatically read, and the tube and sample information recorded by the software.
Furthermore, the conditions when the tube was analyzed can be easily checked.

























 

Supports Sample Tubes from Various Manufacturers

The TD-30 series supports sample tubes (size: 1/4" × 3.5") from various manufacturers. The user can select the optimal tube to suit the application.In addition, TD tubes that the customer already has can be used.














 

Simple Operations and Ease of Maintenance

With the TD-30 Thermal Desorber series, traps, O-rings, and other consumables and maintenance parts can be accessed from the top surface of the instrument, so replacement is simple.
The system is equipped with a software function that records the number of uses of consumables and maintenance parts, and notifies the user when a pre-specified number of uses has been reached. Accordingly, problems due to the operating life of parts can be avoided.





















 

Problems with Tubes Are Prevented Using the Tube Protection Function and the Pressure Release Function

The TD-30 series features a built-in tube protection sensor, which significantly reduces tube damage during cap removal.
In addition, before the tube is removed, the pressure inside the tube is reduced, extending the tube's lifetime.

















 