Thermal Analyzers
|
|
DSC-60
Differential Scanning Calorimeter
The development of a new-model detector
makes it possible to achieve a peak height with twice the sensitivity (compared with other Shimadzu calorimeters) and at a noise level of less than 1μW. The DSC-60 also has a built-in liquid nitrogen
cooling tank so that measurements involving a cooling process can be easily performed. - Temperature Range : -130°C to 600°C
- Measurement Range : ±40mW
- Program
Speed : 0 to 99.9°C/min/°C/hour
- Cooling Time : Approx. 6min. (Using liquid nitrogen to cool the sample from 600°C to 40°C)
- Measurement Atmosphere : Air, Sample in a
nonvolatile gas flow
Download product catalog Print |
|
|
DSC-60A
Automatic Differential Scanning Calorimeter
This is an automatic DSC with built-in autosampler. Generally, a whole day's load of sample (24 samples) can be set with different
measuring conditions for each sample if required. And, operation is easy as a template system enables automatic analysis and automatic printout. - Temperature range : -140 to
600°C
- Measuring range : ±40mW
- Noise level : 1μW (RMS value: the sample temperatur
Download product catalog Print |
|
|
DTG-60/60H
Simultaneous Differential Thermal Analyzer
This device simultaneously performs differential thermal analysis and
thermogravimetric analysis using a differential top-pan balance. The weighing range has been widely increased ( a 2 fold or more increase in comparison with current Shimadzu product) while a stable
baseline has also been achieved. Moreover, a Shimadzu-developed fiow line construction enables the testing with various atmospheric gases. (Note that certain reaction gases cannot be used.)
- Temperature range : Room temperature to 1100°C
- Maximum sample : 1g (including tare)
- Measuring range : TG±500mg, DTA± 1000 μV
Download product catalog Print |
|
|
DTG-60A/AH
Auto Simultaneous TG/DTA
The DTG-60A/60AH is a new automatic DTG which defines new standards in autosampler technology. The built-in automatic sampler can easily be operated and programmed, compared to the
complicated operation and setup of conventional autosamplers. Up to 24 samples can be set up for analysis and additional sample trays can be used to quickly reload the autosampler, providing
more than 24 hours of fully automatic analysis at one time. - Temperature range : Room temperature to 1100°C
- Maximum sample : 1g (including tare)
- Measuring range :
TG±500mg, DTA±1000μV
Download product catalog Print |
|
|
TMA-60/60H
Thermomechanical Analyzer
This analyzer can handle a wide variety of samples and measurement methods and a large temperature range to perform thorough measurement of the mechanical
properties of materials. A highprecision digital sensor allows displacement measurement with a low drift in a wide range. - Temperature Range : Ambient to 1000°C/1500°C from -
140°C with an optional adapter
- Measurement Range : Displacement : ±5mm
- Load : ±5N
- Sample Size : ø8x20mm, 5x1x20mm (60type)
Download product catalog Print |
|
|
TA-60WS
Thermal Analysis Workstation
The TA-60WS uses32-bit application software that is fully compatible with Windows 95. Up to four thermal analyzers can be connected
to the work station, and the station is equipped with multi-channel, multi-task functions that make it possible to make measurements while simultaneously performing analysis. - The
workstation takes full advantage of the outstanding functions of
Windows 95. - Thermal analysis data can be transmitted quickly through Internet
E-mail. - The
software is OLE compatible, making it easy to prepare reports
using analysis data. - The TA-60WS can also be connected to 50-Series thermal
analyzers.
Download product catalog Print |
|
|
TGA-50 / 50H / 51 / 51H
Thermogravimetric Analyzers
Our TGA units have been designed to provide excellent performance
for all aspects related to analysis, from vibration resistance and stability to noise level and fluctuations due to ambient temperature. These units can even clearly detect mass fluctuations as
small as the several μg order (10μg for 51-model units). High-temperature H models are available for ceramic, catalyst, and other high-temperature applications. The 51-model units are
macro-type analyzers. - Temperature Range : Room Temp. to 1000°C/Room Temp. to 1500°C (H-models)
- Measurement Range : ±20mg, ±200mg, (only ±2000mg
(51-models) only
- Maximum Sample Weight : 1g(tare weigtht)/10g (tare weight for 51-models)
Download product catalog Print |
|
|
| |
|
|
|
| |
 |
 |
|