Shimadzu Corporation

GCMS-TQ8040 NX Triple Quadrupole TQ Gas Chromatography Mass Spectrometry

Shimadzu Triple Quadrupol GCMS-TQ8040 NX Gas Chromatography Mass Spectrometer features smart technologies to improve the efficiency of routine analytical work. For example, Smart MRM provides fully automated MRM method development. It automatically determines all optimal transitions and collision energies and integrates them seamlessly into the Smart Database Series. With features like this, the GCMS-TQ8040 NX GC-MS/MS is so smart it's almost self-running! Perfect for applications in areas such as environmental monitoring and food science.

The Shimadzu GCMS-TQ8040 NX is the first triple quadrupole with Smart Productivity for high efficiency sample throughput, Smart Operation for quick and easy method development, and Smart Performance for low detection limits and Scan/MRM.

These 3 smart technologies contribute to Smart MRM, and provide the most accurate, cost effective, and easy-to-use triple quadrupole GCMS you have ever imagined.

  • Smart Productivity: This new firmware protocol enables MRM analysis with up to 32,768 transitions in a single analysis.
  • Smart Performance: The exceptionally efficient ion source and collision cell provide low detection limits. High speed scanning control (ASSP) and simultaneous Scan/MRM analysis mode provides accurate low-level quantitative data in a single analysis.
  • Smart Operation: With Smart MRM, the GCMS-TQ8040 software sets the analytical conditions automatically, making method development painless, fast, and easy.

Time Management during Injection Port Maintenance

The Easy Stop function of gas chromatography mass spectrometry system, used to safely maintain the sample injection port without releasing the vacuum, displays the remaining time (coolingdown time) when the septum or the insert can be replaced in real time. Maintenance time can be minimized by understanding the accurate remaining time.
Furthermore, by using a ClickTek nut on the top of the sample injection port, the port can be opened or closed without tools, by simply using fingers to twist a lever. That enables faster and easier insert replacement than ever before.










 


Active-Time Management™ That Accurately Determines Operation Time

Time Management during Instrument Startup/Shutdown

The mass spectrometer (MS) has to be operated in a vacuum condition, the startup and stopping of the system takes time depending on the condition. Determining this can be a challenge. Since the amount of time that the system takes when starting up or stopping is displayed in real time, it is easy to accurately determine when maintenance of the ion source or analysis is possible. Moreover, tasks that until now needed to be performed by the user, such as leak checks upon system startup and auto tuning, are now performed automatically.











 


Time Management for Continuous Analysis

By displaying the time required for continuous analysis in real time, the time when the current continuous analysis will finish can be accurately confirmed. This increases the instrument operating time (active time) by reducing standby time required during continuous analysis or while switching between different users. In addition, because this function makes it easier to schedule the timing for analysis preparations, such as sample preparation and pretreatment, based on the finish time of the previous analysis, it enables analytical processes to be performed more efficiently, which can help improve work-life balance.
















 

Smart Database

Smart Database Series Provides Automated Method Development

The Shimadzu "Smart Database" is a database file for creating the method files using "Smart MRM" function. In addition to compound information and transitions, retention index can be registered in the database file. Method creation can be proceeded without calculating the retention time by analyzing the standard samples when using the Automatic Adjustment Retention Time (AART) function. In addition to MRM information, Scan and SIM ion information, mass spectra and calibration curve information from the internal standard method can also be registered in the database file. This allows users to create their own database easily.








 


Smart MRM 

Smart MRM sets Method to Maximize Sensitivity

Smart MRM makes method development quick and easy. Whether starting from scratch to optimize transitions and collision energies for new compounds, or starting from an MRM database of known target analytes to build a custom MRM method, Smart MRM takes the stress and difficulty out of method development.

























 


Highly Sensitive and Stable Ion Source

The effect of the filament’s electric potential on the ion source is reduced by placing more distance between the filament and ion source box. In addition, a shield blocks out radiant heat generated from the filament to ensure the ion source box temperature remains uniform. Since this prevents any active spots within the ion source, it provides higher sensitivity for analysis.

















 

High Performance Quadrupole Mass Filter

High precision mass filter with front bar and patented electric field control technology provides high precision mass separation performance.
In addition, front bars minimize quadrupole contamination and eliminate the need for quadrupole maintenance.